Tramex Hygrohood Relative Humidity Floor Box

Hygrohood Relative Humidity Floor Box

Excess Moisture in floor slabs and screeds can cause numerous problems in all types of floor coverings leading to complete floor failure and even structural damage.

It is important that a concrete floor or screed should be sufficiently dry to allow installation of a resilient floor
covering using the insulated impermeable hood method.

PRE-TEST CONDITIONING AND PREPARATION
For best and most accurate results, tests should be carried out after the internal conditions of the building in which
the slab is located have been at normal service temperature and humidity for at least 48 hours.

All artificial heating or drying equipment should be turned off at least 96 hours before final readings are attempted, otherwise results may not accurately reflect the amount of moisture present or moisture movement in the slab during normal operating conditions.

Avoid testing in locations subject to direct sunlight or sources of heat. Use of artificial aids for accelerated drying of concrete is not recommended. If they are being used it is recommended they should be turned off at least four days before taking final readings. It is advantageous to know the background of the site e.g. when the floor or screed was poured, thickness levels, etc.

 




TESTING
1. Before positioning the Hygrohood on the floor slab, the surface should be clear of any foreign materials and
swept clean of any dust or loose materials that could affect a proper seal between the hood and the surface of
the floor.
2. Using butyl tape, seal the insulated Hood to the concrete surface.
3. Once equilibrium is reached Hygrometer can be switched on. The Hygrometer will record minimum and
maximum values while it remains switched on. Optional C°/F° units are available. Memory will be reset when the
unit is switched off.
Always refer to the adhesive and/or floor covering manufacturer’s recommendations for the acceptable moisture
content levels of concrete to floor screeds.

CALIBRATION SPECIFICATION
The Hygrometer is factory calibrated to 75%RH at 20C. The product is designed to remain calibrated for 18 months from date of manufacture. The measuring range 20% - 99%RH, with a temperature range of 0°C - 50°C / 32° - 122°F Tolerances +/- 3%, +/- 1°C / +/- 2°F. Replacement battery CR2032

OUR PRICE (ex. vat):  £158.00
(inc. vat @20%) £189.60
View all products by Tramex
Additional Product Images
 
© 2005 - 2024 Merlin Lazer http://www.merlinlazer.com - Printed: 13 October 2024