| The Flir T250 offers an entry level  solution for professional thermographers who require a versatile camera for conducting electrical and  mechanical inspections but do not need extra IR resolution and extended functions of the Flir T335, Flir T365 or the Flir T425. 
 The Flir T250 Infra-Red camera is a smart, compact and powerful camera  with 1 - 2x continuous, digital zoom, a 240 x 180 IR pixel resolution, a 80mK NETD/0.08°C thermal sensitivity and an extended temperature  measurement range of -20°C to 350°C.
 
 The camera funtionality including a thumbnail image gallery which allows quick searching  of stored images and the 120° rotating lens offers a wide range of  viewing angles.
 The latest FLIR T250 IR Camera is designed to tackle the performance  demands of industrial, plant, and utility professionals responsible for  effective electrical / mechanical inspections and MRO. 
 
 The Flir T250 also features Meterlink allowing the transfer of data  taken with the Extech EX845 clamp meter recording electrical meter  readings direct to the image on the camera thus saving you the time of  recording the measurements manually and the possible errors that can  arise in matching them back to the image when compiling your report.
 
 Industrial applications for the FLIR T-Series
 Examples of industrial applications where the FLIR T-Series cameras are  an invaluable tool for professional thermographers in spotting anomalies  before a break down is a fact, are: production process supervision,  measurement of heat development electrical and mechanical devices,  detect blocked pipe work and insulation defects, enhance work safety and  much more.
 
 
 
 
  
 
 
    
        
            |  |  | MeterLink™: MeterLink is a new Bluetooth technology that lets FLIR  infrared cameras "talk to" EXTECH meters wirelessly. Manual data  collection is time-consuiming and prone to errors. MeterLink™ eliminates  this problem by allowing the thermographer to quickly take moisture  readings on a damaged surface and associate those readings with the  corresponding targets stored in an infrared image.Readings from the  meters get recorded right on the camera's images.
 | 
 
 Features:
 
 
 
 
 What can infrared cameras do for you?
 
 Infrared cameras meet the stringent demands of building diagnostics.  They feature immediate high-resolution thermal imagery, which reveals  potential structural and moisture issues, energy efficiency and even  rodents or pests. Use an infrared camera to find:
 
 
  Moisture 
  Missing or defective insulation 
  Structural shortcomings 
  HVAC problem areas 
  Sourced of heating/cooling losses 
  Plumbing blockages 
  Roof leaks 
  Electrical issues 
  Rodents and other pests 
  And much more! 
 
 Who uses thermal imaging cameras?
 
 
  Building Inspectors 
  Electricians 
  General Contractors 
  Home Efficiency Consultants 
  Plant Maintenance Professionals 
  HVAC/R Contractors 
  Mold Remediation Professionals 
  Plumbers 
 
 Applications:
 
 
  Detect hidden problems, make quick damage assessments 
  Check for overheating of electrical panels and transformers 
  Avoid electrical failures 
  Identify faults in heating and cooling systems 
  Find problems with motors, fans and bearings 
  Generate reports, analyze and document your findings with the easy-to-use software 
 
  Camera specific
    
        
            | Flir T-Series Camera Comparison: |  
            | MODEL | FLIR T250 | FLIR T335 | FLIR T365 | FLIR T425 |  
            |  |  |  |  |  |  
            |  | Selected Model |  more info |  more info |  more info |  
            | Imaging performance |  |  |  |  |  
            | Thermal sensitivity/NETD | 80 mK at 30°C < 0.08 °C
 | 50 mK at 30°C < 0.05 °C
 | 50 mK at 30°C < 0.05 °C
 | 50 mK at 30°C < 0.05 °C
 |  
            | IR resolution | 240 × 180 pixels (43,200) measurement points per image
 | 320 × 240 pixels (76,800) measurement points per image
 | 320 × 240 pixels (76,800) measurement points per image
 | 320 × 240 pixels (76,800) measurement points per image
 |  
            | Zoom | 1–2× continuous, digital zoom, including panning | 1–2× continuous, digital zoom, including panning | 1–4× continuous, digital zoom, including panning | 1–8× continuous, digital zoom, including panning |  
            |  |  |  |  |  |  
            | Image presentation |  |  |  |  |  
            | Image modes | General | General | General + Thermal Fusion | General + Thermal Fusion |  
            | Thermal Fusion | N/A | N/A | IR image shown within temp interval on visual image | IR image shown above, below or within temp interval on visual image |  
            | Picture in Picture | Scalable IR area on visual image | Scalable IR area on visual image | Resizable and movable IR area on visual image | Resizable and movable IR area on visual image |  
            |  |  |  |  |  |  
            | Measurement |  |  |  |  |  
            | Object temperature range | –20 °C to +350 °C in 2 ranges: -20°C to +120°C or 0°C to +350°C | –20 °C to +650 °C in 3 ranges: -20°C to +120°C or 0°C to +350°C or +200°C to +650°C | –20 °C to +650 °C in 3 ranges:-20°C to +120°C or 0°C to +350°C or +200°C to +650°C | –20 °C to +1200 °C in 3 ranges: -20°C to +120°C or 0°C to +350°C or +200°C to +1200°C |  
            |  |  |  |  |  |  
            | Measurement analysis |  |  |  |  |  
            | Difference temperature | N/A | N/A | Delta temperature between measurement functions or reference temperature | Delta temperature between measurement functions or reference temperature |  
            | Measurement function alarm | N/A | N/A | Audible/visual alarm (above/below) on spotmeter, box or difference temperature | Audible/visual alarm (above/below) on spotmeter, box or difference temperature |  
            |  |  |  |  |  |  
            | Set-up |  |  |  |  |  
            | Color palettes | General | General | General | General + RainHC, Bluered |  
            |  |  |  |  |  |  
            | Image storage |  |  |  |  |  
            | Periodic image storage | N/A | N/A | N/A | Every 10 seconds up to 24 hours |  
            |  |  |  |  |  |  
            | Image annotations |  |  |  |  |  
            | Voice | 60 seconds | 60 seconds | 60 seconds | 60 seconds via Bluetooth® |  
            | Image marker | On IR or visual image | N/A | 4 on IR or visual image | 4 on IR or visual image |  
            | Sketch | From touch screen | N/A | From touch screen | From touch screen |  
            |  |  |  |  |  |  
            | Digital camera |  |  |  |  |  
            | Digital camera video recording | N/A | N/A | N/A | Video clip to memory card |  
            |  |  |  |  |  |  
            | Report generation |  |  |  |  |  
            | Instant report | N/A | N/A | .pdf file in camera including thermal and visual image | .pdf file in camera including thermal and visual image |  
  General Specifications
    
        
            | Flir E-Series Non Camera Specific Specifications: |  
            | Imaging Performance |  |  
            | Field of view (FOV) / Minimum focus distance | 25° × 19° / 0.4 m |  
            | Spectral range | 7.5 - 13 µm |  
            | Spatial resolution (IFOV) | 2.18 mrad for T250 - 1.36 mrad for T335, T365, T425 |  
            | Image frequency | 9 Hz or 30 Hz |  
            | Focus | Automatic or manual |  
            | Focal Plane Array (FPA) | Uncoooled microbolometer |  
            |  |  |  
            | Image presentation |  |  
            | Display | Built-in touch screen, 3.5" color LCD, 320 x 240 pixels |  
            | Image modes | IR image, Visual image, Picture in Picture, Thumbnail gallery |  
            |  |  |  
            | Measurement |  |  
            | Accuracy | ±2°C or 2% of reading |  
            |  |  |  
            | Measurement analysis |  |  
            | Spotmeter | 5 |  
            | Area | 5 boxes with max./min./average |  
            | Isotherm | Detect high/low temperature/interval |  
            | Automatic hot / cold detection | Auto hot or cold spotmeter markers within area |  
            | Emissivity correction | Variable from 0.01 to 1.0 or selected from list of materials |  
            | Measurement corrections | Reflected temperature, optics transmission and atmospheric transmission |  
            | External optics/windows correction | Automatic, based on inputs of optics/window transmission and temperature |  
            |  |  |  
            | Setup |  |  
            | Color palettes | BW, BW inv, Iron, Rain , T425: Rain HC, Bluered |  
            | Set-up controls | Local adaptation of units, language, date and time formats; automatic shutdown, display intensity |  
            |  |  |  
            | Image storage |  |  
            | Type | SD memory card |  
            | Format | Standard JPEG - including measurement data |  
            | Modes | IR/visual images, simultaneous storage of IR and visual images |  
            |  |  |  
            | Image annotations |  |  
            | Text | Text from predefined list or soft keyboard on touch screen |  
            | MeterLink | Connect Extech Clamp Meter EX845 or Moisture Meter MO297 via Bluetooth |  
            |  |  |  
            | Digital camera |  |  
            | Built-in digital camera | 3.1 Mpixel (2048 × 1536 pixels), and LED lights |  
            |  |  |  
            | Laser Pointer |  |  
            | Laser | Semiconductor AlGalnP diode laser, Class 2 |  
            | Laser alignment | Position is displayed automtically on the IR image |  
            |  |  |  
            | Power System |  |  
            | Battery time | Rechargeable Lithium-ion battery, field replaceable |  
            | Battery operating time | 4 hours |  
            | Charging system | In camera, AC adaptor, 2-bay charger or 12 V from a vehicle |  
            | Power management | Automatic shutdown (user selectable) |  
            | AC operation | AC adaptor, 100–240 V AC, 50/60 Hz |  
            | Adaptor voltage | 12 Volt VDC out |  
            |  |  |  
            | Environmental specifications |  |  
            | Operating temperature range | -15 °C to +50 °C |  
            | Storage temperature range | -40 °C to +70 °C |  
            | Humidity (operating and storage) | IEC 60068-2-30/24 h 95% relative humidity +25 °C to +40 °C |  
            | Shock | 25 g (IEC 60068-2-29) |  
            | Vibration | 2 g (IEC 60068-2-6) |  
            | Encapsulation | Camera housing and lens: IP 54 (IEC 60529) |  
            |  |  |  
            | Interfaces |  
            | USB-A | Connect external USB device (copy to memory stick) |  
            | USB Mini-B | Data transfer to and from PC/streaming |  
            | Composite video | PAL or NTSC |  
            | Headset connection | Yes |  
            | Physical characteristics |  |  
            | Camera weight, incl. battery | 0.88 kg |  
            | Camera size (L × W × H) | 106 × 201 × 125 mm |  
            | Shipping size | 180 x 500 x 360 mm |  
            | Shipping weight | 5.6 kg |  
            |  |  |     
 
 your shipment will include:
 
  1 no. FLIR T250 Infrared Camera 
  1 no. Protective Carry Case 
  1 no. Bluetooth Headset 
  1 no. SD MemoryCard 
  1 no. USB cable 
  1 no. Video cable 
  1 no. Battery & Charger 
  1 no. Wrist Strap 
  1 no. FLIR QuickReport Software CD-ROM 
  1 no.Getting Started Guide and User´s manual CD in 21 languages 
  1 no.Power supply/charger with EU, UK, US and australian plugs 
  1 no. Flir T250 Calibration Certificate 
  1 no. 24 Month Warranty 
  1 no. 30 Day Money Back Guarantee 
  1 no. Comprehensive FLIR Dealer Technical Advice & Support
   |